1. Feature
- 100MHz bandwidths
- 1GSa/s Real Time sample rate
- Large (7.0-inch) color display,WVGA(800x480)
- Record length up to 40K
- Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
- USB host and device connectivity, standard
- Multiple automatic measurements
- Four math functions, including FFTs standard
- Provides software for PC real-time analysis
- VGA Optional
2. Specifications
Model | DSO5102P |
Acquisition | |
Sample Rate | Real-Time Sample: 1GS/s |
Acquisition Modes | |
Normal | Normal data only |
Peak Detect | High-frequency and randon glith capture |
Average | Wavefom Average, selectable 4,8,16,32,64,128 |
Inputs | |
Inputs Coupling | AC, DC, GND |
Inputs Impendance | 1MΩ±2% ‖20pF±3pF |
Probe Attenuation | 1X, 10X |
Supported Probe Attenuation Factor | 1X, 10X, 100X, 1000X |
Maximum Input Voltage |
CAT I and CAT II: 300VRMS (10×), Installation Category; CAT III: 150VRMS (1×); Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur. |
Horizontal System | |
Sample Rate Range | 500MS/s--1GS/s |
Waveform Interpolation | (sin x)/x |
Record Length | 40K |
SEC/DIV Range | 4ns/div to 40s/div |
Sample Rate and Delay Time Accuracy |
±50ppm(at over any ≥1ms time interval) |
Position Range |
20ns/div to 80us/div; (-8div x s/div) to 40ms; 200us/div to 40s/div; (-8div x s/div) to 400s |
Delta Time Measurement Accuracy (Full Bandwidth) |
Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns); >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns); Sample interval = s/div ÷ 200 |
Vertical System | |
Vertical Resolution | 8-bit resolution, all channel sampled simultaneously |
Position Range | 2mV/div to 10V/div |
Bandwidth | 100MHz |
Rise Time at BNC( typical) | 3.5ns |
Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled |
2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±2V 500mV/div to 2V/div, ±40V; 5V/div, ±50V |
Math | +, -, *, /, FFT |
FFT |
Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample point |
Bandwidth Limit | 20MHz |
Low Frequency Response (-3db) | ≤10Hz at BNC |
DC Gain Accuracy |
±3% for Normal or Average acquisition mode, 5V/div to 10mV/div; ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div |
DC Measurement Accuracy, Average Acquisition Mode |
When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected; When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div |
Volts Measurement Repeatability, Average Acquisition Mode |
Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions |
Trigger System | |
Trigger Types | Edge, Video, Pulse, Slope, Over time, Alternative |
Trigger Source | CH1, CH2, EXT, EXT/5, AC Line |
Trigger Modes | Auto, Normal, Single |
Coupling Type | DC, AC, Noise Reject, HF Reject, LF Reject |
Trigger Sensitivity (Edge Trigger Type) |
DC(CH1,CH2): 1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full; DC(EXT): 200mV from DC to 100MHz; 350mV from 100MHz to 200MHz; DC(EXT/5): 1V from DC to 100MHz;1.75V from 100MHz to 200MHz; AC: Attenuates signals below 10Hz; HF Reject: Attenuates signals above 80kHz LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz |
Trigger Level Range |
CH1/CH2: ±8 divisions from center of screen; EXT: ±1.2V; EXT/5:±6V |
Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns |
CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen; EXT: ± (6% of setting + 40mV); EXT/5: ± (6% of setting + 200mV); |
Set Level to 50%(typical) | Operates with input signals ≥50Hz |
Video Trigger | |
Video Trigger Type |
CH1, CH2: Peak-to-peak amplitude of 2 divisions; EXT: 400mV; EXT/5: 2V |
Signal Formats and Field Rates, Video Trigger Type | Supports NTSC, PAL and SECAM broadcast systems for any field or any line |
Holdoff Range | 100ns ~ 10s |
Pulse Width Trigger | |
Pulse Width Trigger Mode | Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse |
Pulse Width Trigger Point |
Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level. Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width. Less than: The trigger point is the trailing edge. Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width |
Pulse Width Range | 20ns ~ 10s |
Slope Trigger | |
Slope Trigger Mode | Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope |
Slope Trigger Point |
Equal: The oscilloscope triggers when the waveform slope is equal to the set slope. Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope. Less than: The oscilloscope triggers when the waveform slope is less than the set slope. Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope. |
Time Range | 20ns ~ 10s |
Overtime Trigger | |
Over Time Mode | Rising edge or Falling edge |
Time Range | 20ns ~ 10s |
Alternative Trigger | |
Trigger on CH1 | Internal Trigger: Edge, Pulse Width, Video, Slope |
Trigger on CH2 | Internal Trigger: Edge, Pulse Width, Video, Slope |
Trigger Frequency Counter | |
Readout Resolution | 6 digits |
Accuracy (typical) | ±30ppm (including all frequency reference errors and ±1 count errors) |
Frequency Range | AC coupled, from 4Hz minimum to rated bandwidth |
Signal Source |
Oscilloscope HANTEK DSO5102P
- Brand: Hantek
- Product Code: DSO5102P
- Availability: In Stock
-
Rp4,500,000
Related Products
Tags: Oscilloscope HANTEK DSO5102P
Featured
Reflectance Meter Landtek RM-206
Alat ukur transparansi/ reflektifitas Digunakan untuk produk Plastik, Film, Coating, dll untu..
Rp9,900,000 Ex Tax: Rp9,900,000
Ultra Low Temperature Data Logger Tzone TempU06 L100
- Original TZONE versi Bahasa Inggris - Mendapatkan Sertifikat Kalibrasi yg berstandar NIST U..
Rp850,000 Ex Tax: Rp850,000
Magnetic Field Meter Tenmars TM-197
Original Tenmars Masih Made in Taiwan Bersertifikat Alat ukur medan..
Rp6,700,000 Ex Tax: Rp6,700,000
Battery Tester Ancel with Thermal Printer BST500
Alat ukur daya baterai dari ANCEL. Mudah digunakan Ideal untuk segala mobil dan truk. ..
Rp2,100,000 Ex Tax: Rp2,100,000
Vibration Calibrator Landtek VMC606
Alat kalibrasi Vibration Tester dari Landtek Memenuhi syarat industrial CE Menggunakan 4 ..
Rp9,100,000 Ex Tax: Rp9,100,000
Car Battery Tester AUTOOL BT860 with Printer
Car Battery Tester dengan layar LCD berwarna dan printer == AUTO BATTERY LOAD ..
Rp2,300,000 Ex Tax: Rp2,300,000
Laser Distance Meter CEM LDM100H
- Alat ukur jarak dimensi ruang dari brand CEM Instruments yang dikenal dengan kualitas baik ..
Rp1,000,000 Ex Tax: Rp1,000,000
Halogen Moisture Analyzer Joanlab MBA1002
Halogen Moisture Analyzer adalah alat ukur kadar air pada suatu material serbuk, makanan, hasil b..
Rp7,900,000 Ex Tax: Rp7,900,000
Gas Detector 4 In 1 Bosean BH-4M - H2S O2 CO LEL
Detektor 4 macam gas dari Bosean. Model terbaru. Industrial grade Anti-slip grip ru..
Rp3,700,000 Ex Tax: Rp3,700,000
Density Meter MH-300A
Density Meter digunakan untuk mengukur kepadatan atau massa jenis suatu material D..
Rp6,800,000 Ex Tax: Rp6,800,000
Salt Meter Kedida CT-3086 - Ukur Kadar Garam 0-5%
Kedida Tipe CT-3086 mengukur kadar garam dengan rentang 0.0 sampai 5.0% (Kami juga..
Rp870,000 Ex Tax: Rp870,000
Air Flow Meter MF5708
Alat pengukur laju oksigen/ nitrogen/ gas lain dengan display digital yang mudah dipakai dan ..
Rp4,900,000 Ex Tax: Rp4,900,000
Particle Counter CEM Instruments DT-9881
- Particle Counter spesifikasi tinggi dari CEM Instruments. Kualitas Industrial - Mengukur pa..
Rp25,000,000 Ex Tax: Rp25,000,000
Open Channel Flow Meter FM100V5
Open Channel Flow Meter digunakan untuk mengukur aliran air terbuka, Misalkan berupa parit, kanal..
Rp5,600,000 Ex Tax: Rp5,600,000
Infrared Sterilizer Joanlab DS900S
Sterilizer praktis dan efisien untuk alat lab, jarum, tabung dll Bahan stainless steel, mater..
Rp2,100,000 Ex Tax: Rp2,100,000
Ultrasonic Cleaner GT Sonic 20L Digital
- Note: Berat/Volume produk ini +-20kg Mesin pembersih dengan teknologi ul..
Rp11,000,000 Ex Tax: Rp11,000,000
Tablet Friability Tester CS-2
Alat uji kerapuhan tablet, umumnya untuk mengukur ketahanan permukaan tablet terhadap gesekan yan..
Rp9,800,000 Ex Tax: Rp9,800,000
Refractometer Alcohol 0-80%
Refraktometer 0-80 % ini mengukur kadar alkohol dari minuman/cairan. Ideal untuk industri mak..
Rp270,000 Ex Tax: Rp270,000
Earth Resistance Tester Peakmeter PM2302/MS2302
Digital Earth Ground Resistance Tester With 2 Pole And 3 Pole Mode English User Ma..
Rp2,500,000 Ex Tax: Rp2,500,000
Water Bath With Magnetic Stirrer Joanlab WBS-6Pro
Water Bath adalah alat laboratorium berbentuk wadah berisi air panas. Digunakan untuk menginkubas..
Rp5,000,000 Ex Tax: Rp5,000,000
Magnetic Field Meter Tenmars TM191A
Original TENMARS - Made in Taiwan - Bersertifikat TM-191A adalah versi upgrade terbaru dari m..
Rp2,280,000 Ex Tax: Rp2,280,000
H2S Fixed Gas Detector Bosean K-G60
- Tipe ini mendeteksi gas H2S Hydrogen Sulfide (Kami juga jual tipe gas lain: CO O2 LEL CL2 C..
Rp6,000,000 Ex Tax: Rp6,000,000
Gas Detector 4 in 1 Bosean BH4S + Gas Sampling Pump
NOTE: Paket ini termasuk Gas Detector Bosean BH4S, dan Gas Sampling Pump Bosean BH-GSP Bila h..
Rp5,200,000 Ex Tax: Rp5,200,000
Dew Point Meter Landtek HT6292
Alat Ukur Titik Embun atau Dew Point Meter kelas industrial dari pabrikan Landtek ..
Rp3,300,000 Ex Tax: Rp3,300,000
Paper Moisture Meter MD916 - Kadar Air Kertas Karton Kardus
Pengukur kadar air untuk Kertas, Karton, Kardus, Kayu, Tembakau dll Dengan sensor ..
Rp530,000 Ex Tax: Rp530,000
O2 Fixed Gas Detector Bosean K-G60
- Tipe ini mendeteksi gas O2 (Oksigen) dengan rentang 0-30% (Kami juga jual tipe gas lain: CO O..
Rp6,000,000 Ex Tax: Rp6,000,000
Tachometer Data Logger Peakmeter PM6208A
Alat ukur putaran RPM dengan fungsi data logger dari Peakmeter * PM6208A / MS6208A..
Rp530,000 Ex Tax: Rp530,000