1. Feature
- 100MHz bandwidths
- 1GSa/s Real Time sample rate
- Large (7.0-inch) color display,WVGA(800x480)
- Record length up to 40K
- Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
- USB host and device connectivity, standard
- Multiple automatic measurements
- Four math functions, including FFTs standard
- Provides software for PC real-time analysis
- VGA Optional
2. Specifications
Model | DSO5102P |
Acquisition | |
Sample Rate | Real-Time Sample: 1GS/s |
Acquisition Modes | |
Normal | Normal data only |
Peak Detect | High-frequency and randon glith capture |
Average | Wavefom Average, selectable 4,8,16,32,64,128 |
Inputs | |
Inputs Coupling | AC, DC, GND |
Inputs Impendance | 1MΩ±2% ‖20pF±3pF |
Probe Attenuation | 1X, 10X |
Supported Probe Attenuation Factor | 1X, 10X, 100X, 1000X |
Maximum Input Voltage |
CAT I and CAT II: 300VRMS (10×), Installation Category; CAT III: 150VRMS (1×); Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur. |
Horizontal System | |
Sample Rate Range | 500MS/s--1GS/s |
Waveform Interpolation | (sin x)/x |
Record Length | 40K |
SEC/DIV Range | 4ns/div to 40s/div |
Sample Rate and Delay Time Accuracy |
±50ppm(at over any ≥1ms time interval) |
Position Range |
20ns/div to 80us/div; (-8div x s/div) to 40ms; 200us/div to 40s/div; (-8div x s/div) to 400s |
Delta Time Measurement Accuracy (Full Bandwidth) |
Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns); >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns); Sample interval = s/div ÷ 200 |
Vertical System | |
Vertical Resolution | 8-bit resolution, all channel sampled simultaneously |
Position Range | 2mV/div to 10V/div |
Bandwidth | 100MHz |
Rise Time at BNC( typical) | 3.5ns |
Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled |
2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±2V 500mV/div to 2V/div, ±40V; 5V/div, ±50V |
Math | +, -, *, /, FFT |
FFT |
Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample point |
Bandwidth Limit | 20MHz |
Low Frequency Response (-3db) | ≤10Hz at BNC |
DC Gain Accuracy |
±3% for Normal or Average acquisition mode, 5V/div to 10mV/div; ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div |
DC Measurement Accuracy, Average Acquisition Mode |
When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected; When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div |
Volts Measurement Repeatability, Average Acquisition Mode |
Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions |
Trigger System | |
Trigger Types | Edge, Video, Pulse, Slope, Over time, Alternative |
Trigger Source | CH1, CH2, EXT, EXT/5, AC Line |
Trigger Modes | Auto, Normal, Single |
Coupling Type | DC, AC, Noise Reject, HF Reject, LF Reject |
Trigger Sensitivity (Edge Trigger Type) |
DC(CH1,CH2): 1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full; DC(EXT): 200mV from DC to 100MHz; 350mV from 100MHz to 200MHz; DC(EXT/5): 1V from DC to 100MHz;1.75V from 100MHz to 200MHz; AC: Attenuates signals below 10Hz; HF Reject: Attenuates signals above 80kHz LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz |
Trigger Level Range |
CH1/CH2: ±8 divisions from center of screen; EXT: ±1.2V; EXT/5:±6V |
Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns |
CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen; EXT: ± (6% of setting + 40mV); EXT/5: ± (6% of setting + 200mV); |
Set Level to 50%(typical) | Operates with input signals ≥50Hz |
Video Trigger | |
Video Trigger Type |
CH1, CH2: Peak-to-peak amplitude of 2 divisions; EXT: 400mV; EXT/5: 2V |
Signal Formats and Field Rates, Video Trigger Type | Supports NTSC, PAL and SECAM broadcast systems for any field or any line |
Holdoff Range | 100ns ~ 10s |
Pulse Width Trigger | |
Pulse Width Trigger Mode | Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse |
Pulse Width Trigger Point |
Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level. Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width. Less than: The trigger point is the trailing edge. Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width |
Pulse Width Range | 20ns ~ 10s |
Slope Trigger | |
Slope Trigger Mode | Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope |
Slope Trigger Point |
Equal: The oscilloscope triggers when the waveform slope is equal to the set slope. Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope. Less than: The oscilloscope triggers when the waveform slope is less than the set slope. Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope. |
Time Range | 20ns ~ 10s |
Overtime Trigger | |
Over Time Mode | Rising edge or Falling edge |
Time Range | 20ns ~ 10s |
Alternative Trigger | |
Trigger on CH1 | Internal Trigger: Edge, Pulse Width, Video, Slope |
Trigger on CH2 | Internal Trigger: Edge, Pulse Width, Video, Slope |
Trigger Frequency Counter | |
Readout Resolution | 6 digits |
Accuracy (typical) | ±30ppm (including all frequency reference errors and ±1 count errors) |
Frequency Range | AC coupled, from 4Hz minimum to rated bandwidth |
Signal Source |
Oscilloscope HANTEK DSO5102P
- Brand: Hantek
- Product Code: DSO5102P
- Availability: In Stock
-
Rp4,500,000
- Ex Tax: Rp4,500,000
Related Products
Signal Generator Calibration Mr Signal MR9270S+
**Spesifikasi teknis bisa dicek di foto ke 3** * MR9270S+ features 2.4" IPS LCD large..
Rp3,900,000 Ex Tax: Rp3,900,000
Clamp Multimeter Mastech MS2015A
Tang Ampere dari Mastech yang berkualitas baik Features: 6000 counts displa..
Rp800,000 Ex Tax: Rp800,000
Clamp Multimeter AC/DC Mastech MS2138R
Clamp Multimeter Mastech MS2138R Tang Ampere AC DC berkualitas Industrial dari Mastech S..
Rp1,700,000 Ex Tax: Rp1,700,000
Multimeter with Environment Tester 5 in 1 Mastech MS8229
Multimeter 5 in 1 dengan berbagai macam fitur: 1. Fitur Thermometer: mengukur suhu lingkungan ..
Rp1,100,000 Ex Tax: Rp1,100,000
Multimeter Mastech MS8268
- Multi-functional: Including measurements of AC/DC voltage and current, resistance, capacitance, fr..
Rp900,000 Ex Tax: Rp900,000
Signal Generator FeelTech FY3200S
Description: This manual applies to each mode of FY3200S series DDS Function Signal G..
Rp1,250,000 Ex Tax: Rp1,250,000
PC USB Oscilloscope Hantek 6022BL
Osiloskop adalah alat untuk memetakan atau memproyeksikan sinyal listrik dan frekuensi menjadi gamba..
Rp1,500,000 Ex Tax: Rp1,500,000
Three Phase Rotation Indicator Peakmeter PM5900
Features: PM5900 Motor and Phase Rotation Indicator is used to test magnetic field direction o..
Rp430,000 Ex Tax: Rp430,000
PC Based USB Digital Oscilloscope Intrustar ISDS205B
PC Oscilloscope dari brand Intrustar, Tipe ISDS205B dengan 5 fungsi: - Spectrum Analyzer - D..
Rp1,400,000 Ex Tax: Rp1,400,000
Signal Generator Feeltech FY3224S
Versi ini rentang frekuensi sampai 24MHz Fitur: Output frekuensi sinyal akurasi t..
Rp1,300,000 Ex Tax: Rp1,300,000
Spectrum Analyzer RF Explorer WSUB1G
Spectrum Analyzer adalah alat ukur untuk mengetahui jumlah distribusi energi dari suatu spektrum fre..
Rp4,100,000 Ex Tax: Rp4,100,000
Signal Generator Feeltech FY6600-60M 60MHZ
Generator sinyal FY6600-60Mhz dari Feeltech Model ini rentang frekuensi sampai 60MHz (versi pali..
Rp2,200,000 Ex Tax: Rp2,200,000
PC Based USB Digital Oscilloscope Intrustar ISDS205A
Intrustar ISDS205A adalah Osiloskop dual channel dengan harga terjangkau dan performa baik. &nb..
Rp1,200,000 Ex Tax: Rp1,200,000
Voltage Detector MESTEK AC20
Tes pen voltase tanpa sentuh dari MESTEK Dengan berbagai fitur: - Tahan air - Water Resistan..
Rp150,000 Ex Tax: Rp150,000
Tags: Oscilloscope HANTEK DSO5102P
Featured
Air Flow Meter MF5708
Alat pengukur laju oksigen/ nitrogen/ gas lain dengan display digital yang mudah dipakai dan ..
Rp4,900,000 Ex Tax: Rp4,900,000
Particle Counter CEM Instruments DT-9881
- Particle Counter spesifikasi tinggi dari CEM Instruments. Kualitas Industrial - Mengukur pa..
Rp25,000,000 Ex Tax: Rp25,000,000
Ultrasonic Cleaner GT Sonic 20L Digital
- Note: Berat/Volume produk ini +-20kg Mesin pembersih dengan teknologi ul..
Rp11,000,000 Ex Tax: Rp11,000,000
Tablet Friability Tester CS-2
Alat uji kerapuhan tablet, umumnya untuk mengukur ketahanan permukaan tablet terhadap gesekan yan..
Rp9,800,000 Ex Tax: Rp9,800,000
Magnetic Field Meter Tenmars TM191A
Original TENMARS - Made in Taiwan - Bersertifikat TM-191A adalah versi upgrade terbaru dari m..
Rp2,280,000 Ex Tax: Rp2,280,000
Gas Detector 4 in 1 Bosean BH4S + Gas Sampling Pump
NOTE: Paket ini termasuk Gas Detector Bosean BH4S, dan Gas Sampling Pump Bosean BH-GSP Bila h..
Rp5,200,000 Ex Tax: Rp5,200,000
O2 Fixed Gas Detector Bosean K-G60
- Tipe ini mendeteksi gas O2 (Oksigen) dengan rentang 0-30% (Kami juga jual tipe gas lain: CO O..
Rp6,000,000 Ex Tax: Rp6,000,000
Humidity Temperature Data Logger Elitech RC51H
- Original Elitech dengan Sertifikat Kalibrasi- Merekam dan mengolah data suhu & kelembaban dala..
Rp650,000 Ex Tax: Rp650,000
Soil Hardness Tester Landtek FM204TR
Alat pengukur Kekerasan Tanah dengan satuan Kg/Cm2, untuk analisa kondisi tanah. Ideal untuk ko..
Rp7,000,000 Ex Tax: Rp7,000,000
Coal Moisture Meter MS350
Moisture Tester yang dirancang spesifik untuk mengukur kadar air pada material Tepung Batu Bara, Tan..
Rp2,300,000 Ex Tax: Rp2,300,000
PAR Meter APM130
Instrumen untuk mengukur intensitas radiasi efektif fotosintesis pada cahaya alami atau simulasi cah..
Rp2,400,000 Ex Tax: Rp2,400,000
Ultra Low Temperature Data Logger Tzone TempU06 L100
- Original TZONE versi Bahasa Inggris - Mendapatkan Sertifikat Kalibrasi yg berstandar NIST U..
Rp850,000 Ex Tax: Rp850,000
Reflectance Meter Landtek RM-206
Alat ukur transparansi/ reflektifitas Digunakan untuk produk Plastik, Film, Coating, dll untu..
Rp9,900,000 Ex Tax: Rp9,900,000
Laser Distance Meter Fluke 406E
Alat ukur dimensi jarak dari FlukeMengukur sampai 60 MeterFluke 406E dapat dipasang di sabuk peralat..
Rp1,320,000 Ex Tax: Rp1,320,000
Car Battery Tester AUTOOL BT860 with Printer
Car Battery Tester dengan layar LCD berwarna dan printer == AUTO BATTERY LOAD ..
Rp2,300,000 Ex Tax: Rp2,300,000
Gold Purity Tester JH300A
Solid / Liquid/ Gold/ Powder DensitometerDigunakan untuk mengukur kepadatan atau massa jenis suatu m..
Rp4,800,000 Ex Tax: Rp4,800,000
Salt Meter Kedida CT-3086 - Ukur Kadar Garam 0-5%
Kedida Tipe CT-3086 mengukur kadar garam dengan rentang 0.0 sampai 5.0% (Kami juga..
Rp870,000 Ex Tax: Rp870,000
Tablet Hardness Tester YD-1
Alat ukur kekerasan tablet. Umum digunakan pada industri farmasi. Dalam menjaga ku..
Rp11,700,000 Ex Tax: Rp11,700,000
Tachometer 2 in 1 TASI TA500C
Tachometer dengan 2 mode pakai:1. Contact via Laser2. Non Contact via Sentuh==Easy-to-use instrument..
Rp460,000 Ex Tax: Rp460,000
Vibration Meter Landtek VM-6360 with Software and RS232 Cable
- Versi lengkap dengan kabel data USB RS232, dan CD software Vibration Meter..
Rp5,400,000 Ex Tax: Rp5,400,000
Temperature Data Logger Tzone TempU 90 Days
- Original TZONE- Plug and play, tanpa software: Otomatis memberikan laporan PDF- Ideal untuk pergud..
Rp210,000 Ex Tax: Rp210,000
Lux Meter Data Logger TASI TA632B
Alat pengukur intensitas cahaya dengan fungsi data logging, bisa koneksi ke PC untuk olah data ..
Rp750,000 Ex Tax: Rp750,000
Open Channel Flow Meter FM100V5
Open Channel Flow Meter digunakan untuk mengukur aliran air terbuka, Misalkan berupa parit, kanal..
Rp5,600,000 Ex Tax: Rp5,600,000
Refractometer Alcohol 0-80%
Refraktometer 0-80 % ini mengukur kadar alkohol dari minuman/cairan. Ideal untuk industri mak..
Rp270,000 Ex Tax: Rp270,000
Water Bath With Magnetic Stirrer Joanlab WBS-6Pro
Water Bath adalah alat laboratorium berbentuk wadah berisi air panas. Digunakan untuk menginkubas..
Rp5,000,000 Ex Tax: Rp5,000,000
10000 Gram 10 Kg Calibration Weight
Bandul 10.000 gram (10 kilogram) untuk kalibrasi Timbangan atau keperluan Lab Analitikal lain ..
Rp1,200,000 Ex Tax: Rp1,200,000
Vibration Calibrator Landtek VMC606
Alat kalibrasi Vibration Tester dari Landtek Memenuhi syarat industrial CE Menggunakan 4 ..
Rp9,100,000 Ex Tax: Rp9,100,000
Ultrasonic Thickness Gauge Smart Sensor AR860
Thickness Gauge Ultrasonik dari Smart Sensor. Mendapatkan sertifikat kalibrasi. SM..
Rp3,700,000 Ex Tax: Rp3,700,000
Anemometer Data Logger Holdpeak HP856A
Alat ukur kecepatan angin dengan fungsi Data Logger (Bisa simpan dan olah data) Mengukur bebe..
Rp1,200,000 Ex Tax: Rp1,200,000
Ultrasonic Cleaner GT Sonic 9L Digital
Mesin pembersih dengan teknologi ultrasonik untuk alat lab, elektronik, spare part, alat kesehata..
Rp5,500,000 Ex Tax: Rp5,500,000