Ultrasonic Flowmeter TDS-100F dengan M2 Transducer DN50-700mm

 

Liquid Flow Meter adalah alat untuk mengukur laju aliran atau jumlah suatu fluida yang bergerak mengalir
 
Jenis cairan yang diukur oleh flow meter bisa berbagai macam cairan seperti air minum, air limbah, air lumpur, susu, cairan kimia, air gula, alkohol, oli dll
 
 
Ultrasonic Flow Meter TDS-100F mengukur laju aliran cairan dengan metode ultrasonik. Memiliki kelas proteksi unit yang kedap air IP65.

 

 

Specification:

 

Linearity

Better than ±1%.

Accuracy 

±1% of reading at rates >0.6 ft/s (0.2m/s). Assume a fully developed flow profile.

Repeatability

±0.2%.

Velocity

±0.03 ~ ±105 ft/s 
(±0.01 ~ ±30 m/s), bi-directional

Measurement Period

0.5s

Display

LCD with backlight.  2x20 letters.

Keypad

4x4-key membrane keypad with 
tactile feedback

Units

English (U.S.) or metric.

Outputs

Analogue output: 4-20mA or 0-20mA current output. Impedance 0~1kW. Accuracy 0.1%. .

Isolated OCT output: for frequency output (0~9,999Hz), alarm driver, or totaliser pulse output, ON/OFF control, etc.
Relay output 1A@125VAC or 2A@30VDC. For ON/OFF control, alarm driver, totaliser output, etc.

Internal Alarm (Buzzer): user programmable.
External Alarm Driver: alarm signal can be transmitted to Relay or OCT output terminals to drive an external alarm. 

RS-232 serial port. 

Input

Five channel 4-20mA current inputs for signals such as temperature, pressure, liquid level, and etc.. Accuracy 0.1%.
Two of the five input channels are wired to terminal blocks. The remaining three channels are optional.

Enclosure

Die-cast aluminum enclosure.

Protection Class:  IP65 (NEMA 4X).

Size: 9.88x7.56x3.15 (251x192x80mm3) for standard version

Clamp-on

S2-type: for pipe size  (DN15~DN100mm)

M2-type: for pipe size (DN50~DN700mm)

L2-type: for pipe size (DN300~DN6,000mm)

Liquid Types 

Virtually all commonly used clean liquids.

Liquids with small quantity of tiny particles may also be applicable. Particle size should be less than 75um, particle concentration less than 10,000ppm. 

Liquids should contain no or very minor air bubbles.

Examples are chilled/hot water, sea water, waste water, chemical liquids, oil, crude oil, alcohol, beer, etc.

Liquid Temp

(0C - 160C) for clamp-on transducer. Higher temperatures can be accommodated. Consult us for assistance.

(0C - 160C) for wetted transducer.

Pipe Size 

1 ~ 240 (DN15mm ~ DN6,000mm).

Pipe Material

All metals, most plastics, fiber glass, etc.  Allow pipe liner.

Cable

Shielded transducer cable. Standard length 15 (5m). Can be extended to 1640 (500m).  Contact us for longer cable requirement.

Power

AC: 240V DC: 8VDC~36VDC

Power consumption: < 2W

Weight

Standard main unit: 6.6lb (3kg) 

 

Transducer

Standard S2 type

Standard M2 type